Availability: | |
---|---|
Structure description:
The LW vertical non-clogging sewage pump is a single-suction volute pump. The pump is equipped with a non-clogging and anti-winding single (double) large flow channel impeller, which has good throughput capacity.
The LW vertical non-clogging sewage pump has two structural forms. One is that the motor and the pump are directly coaxial, and the other is connected by a coupling, and the motor uses a standard vertical motor.The structural diagram is as follows. Each structural form has two base connection forms. One is for horizontal suction at the inlet, with a corner function. The inlet and outlet can be placed at 0°, 90°, 180°, and 270° according to the usage requirements, which is convenient for pipelines. connection, the second is the axial suction of the inlet, which facilitates vertical installation.
Features: 1. The mechanical seal adopts a new type of grinding pair and runs in the oil chamber for a long time; 2. The overall structure is compact, small in size, low in noise, significant in energy saving effect, easy to maintain, and convenient for users to replace; 3. It adopts a double-blade impeller structure. Greatly improves the passage capacity of dirt; 4. The automatic control cabinet can automatically control the overrunning and stopping of the pump according to the required liquefaction changes, without the need for special supervision, and is extremely convenient to use; 5. The installation method can be equipped according to the needs of the user. It brings great convenience to installation and maintenance, and people do not have to enter the sewage pit; 6. It can be used within the design range and ensures that the motor will not be overloaded; 7. The pump is equipped with an outdoor motor, so there is no need to build a pump. Room, can be directly installed and used outdoors to save money.
Conditions of Use: 1. LW vertical sewage pump series products are suitable when the rated voltage is 380V and the power frequency is 50Hz; 2. The medium temperature does not exceed 40 degrees Celsius, the medium density is ≤1150kg/m3, and the PH value is within the range of 5-9; 3. The altitude does not exceed 1,000 meters; 4. The annual viscosity of the conveyed medium does not exceed 1,000CP; 5. The product material is mainly cast iron and cannot be used in highly corrosive or highly corrosive media.
Note: Before selecting or installing the pump, make sure the actual operating conditions of the pump comply with the above terms to ensure the correct use of the product.
Structure description:
The LW vertical non-clogging sewage pump is a single-suction volute pump. The pump is equipped with a non-clogging and anti-winding single (double) large flow channel impeller, which has good throughput capacity.
The LW vertical non-clogging sewage pump has two structural forms. One is that the motor and the pump are directly coaxial, and the other is connected by a coupling, and the motor uses a standard vertical motor.The structural diagram is as follows. Each structural form has two base connection forms. One is for horizontal suction at the inlet, with a corner function. The inlet and outlet can be placed at 0°, 90°, 180°, and 270° according to the usage requirements, which is convenient for pipelines. connection, the second is the axial suction of the inlet, which facilitates vertical installation.
Features: 1. The mechanical seal adopts a new type of grinding pair and runs in the oil chamber for a long time; 2. The overall structure is compact, small in size, low in noise, significant in energy saving effect, easy to maintain, and convenient for users to replace; 3. It adopts a double-blade impeller structure. Greatly improves the passage capacity of dirt; 4. The automatic control cabinet can automatically control the overrunning and stopping of the pump according to the required liquefaction changes, without the need for special supervision, and is extremely convenient to use; 5. The installation method can be equipped according to the needs of the user. It brings great convenience to installation and maintenance, and people do not have to enter the sewage pit; 6. It can be used within the design range and ensures that the motor will not be overloaded; 7. The pump is equipped with an outdoor motor, so there is no need to build a pump. Room, can be directly installed and used outdoors to save money.
Conditions of Use: 1. LW vertical sewage pump series products are suitable when the rated voltage is 380V and the power frequency is 50Hz; 2. The medium temperature does not exceed 40 degrees Celsius, the medium density is ≤1150kg/m3, and the PH value is within the range of 5-9; 3. The altitude does not exceed 1,000 meters; 4. The annual viscosity of the conveyed medium does not exceed 1,000CP; 5. The product material is mainly cast iron and cannot be used in highly corrosive or highly corrosive media.
Note: Before selecting or installing the pump, make sure the actual operating conditions of the pump comply with the above terms to ensure the correct use of the product.